Terragene Sterilisation Control – Chemical Indicators
Self-contained chemical indicators for monitoring steam sterilisation processes
![]() |
![]() |
![]() |
![]() |
![]() |
|
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Features
External Use – Tapes and Labels (Type 1)
- Terragene Cintape self-adhesive tapes have been designed to wrap and seal sterilisation packages, as well as to distinguish between items that have been exposed to sterilisation process from those that have not.
- The adhesive on Terragene Cintape allows adhesion to different types of packaging and wraps such as cloth, paper and plastic.
- Terragene Cintape is single use, easy to remove and leaves no residue.
- The innovative, highly sensitive ink on the tapes are designed to turn a different colour when the tape indicator is exposed to the suited sterilisation process.
CT40 – Plasma or Vaporised Hydrogen Peroxide, 50°C, 6 minutes, 2.3 mg/l H₂O₂, Purple to Green
CT22 – Steam, 121°C for 10 minutes, 134°C for 2 minutes, Yellow to Dark Brown/Black
CT10 – Ethylene Oxide, 600 mg/l EO, 60% RH, 54°C, 20 minutes or 600 mg/l EO, 60% RH, 37°C, 25 minutes, Orange to Green
CT50 – Formaldehyde (LTSF), 15 min., 70°C, 1,0 mol/l FORM, Brown/Red to Green
CT30 – Dry Heat, 40 minutes, 160°C €“ 20 minutes, 180°C, Blue to Brown
CD227 – Chemical Indicator, Steam, 121°C for 10 minutes, 134°C for 2 minutes, Blue to Dark Brown/Black
CD27 – Chemical Indicator, Steam, 121°C for 10 minutes, 134°C for 2 minutes, Purple to Green
CD37 – Chemical Indicator, Dry Heat, 160°C, 40 minutes, Violet to Brown
CD17 – Chemical Indicator, Ethylene Oxide (EtO / EO), 600 mg/l EO, 60% RH, 54°C, 20 minutes or 600 mg/l EO, 60% RH, 37°C, 25 minutes, Pink to Orange
CD77 – Chemical Indicator, Gamma Radiation, ‰¥10 kGy., Yellow to Red/Orange
CD47 – Chemical Indicator, Hydrogen Peroxide (H₂O₂), 6 minutes, 50°C, 2.3 mg/l H₂O₂, Purple to Green
CD57 – Formaldehyde (LTSF), 15 min., 70°C, 1,0 mol/l FORM, Bordeaux/Red to Green
CG3 – Three Line Labeler for Sterilisation Package labelling
CD13 – Double Self Adhesive Indicator Label, Printable, Ethylene Oxide (EtO / EO), Light Blue to Green
CD23 – Double Self Adhesive Indicator Label, Printable, Steam, Pink to Dark Brown
CD33 – Double Self Adhesive Indicator Label, Printable Dry Heat, Blue to Brown
CD43 – Double Self Adhesive Indicator Label, Printable, Hydrogen Peroxide (H₂O₂), Purple to Green
CD53 – Double Self Adhesive Indicator Label, Printable, Formaldehyde (LTSF), Bordeaux/Red to Green
CD83 – Double Self Adhesive Indicator Label, Printable, UV-C Disinfection, Yellow to Orange/Red
Bowie & Dick Tests (Type 2)
- Terragene Chemdye Bowie & Dick tests were developed to control air removal and steam penetration performance in vacuum-assisted steam sterilisers.
- Terragene Chemdye Bowie & Dick tests are single-use devices that consist of a lead free chemical indicator, BD test sheet, placed between porous sheets of paper, wrapped with crepe paper with a Steam indicator label on the top of the package.
- Terragene Chemdye Bowie & Dick BD125X/1 also includes a warning sheet which contains a circular lead free chemical indicator, which allows an early detection of air removal failures before they appear on the central chemical indicator.
BD125X/1 – Cycles of 132°C for 4 minutes and 134°C at 3.5 minutes with Warning Sheet, from Yellow to Dark Brown/Black, ISO 11140-5
BD125X/2 – Cycles of 16.9 minutes at 121°C, 4 minutes at 134°C and 3.5 minutes at 134°C, from Yellow to Dark Brown/Black, ISO 11140-4
BD125X10/2 – Cycles of 10 minutes at 121°C, from Yellow to Dark Brown/Black, ISO 11140-4
BDA4 – A4 Size, Cycles of 3.5 minutes at 134°C, 4 minutes at 132°C, from Yellow to Dark Brown/Black, ISO 11140-3
BDA4/1 – A4 Size, Cycles of 3.5 minutes at 134°C, 4 minutes at 132°C, from Yellow to Dark Brown/Black, ISO 11140-5
BDA51 – A5 Size, Cycles of 3.5 minutes at 134°C, 4 minutes at 132°C, from Yellow to Dark Brown/Black
Bowie & Dick Test Card (Type 2)
- Terragene Chemdye Bowie & Dick Test Card has been designed to monitor the effectiveness of air removal in vacuum-assisted steam sterilisers at 132°C for 4 minutes and at 134°C at 3.5 minutes.
- Chemdye Bowie & Dick Test Card consists of a Type 2 metal free chemical indicator printed on one side of the card.
- The Chemical indicator will change from purple to green when processed.
- A non-uniform colour change with Terragene’s Chemdye Bowie & Dick Test Card indicates presence of an air pocket during the sterilisation cycle, therefore indicating sterilisation malfunction.
BD8948X – Steam Sterilisers operating at 3.5 minutes at 134°C and 4 minutes at 132°C, Purple to Green, ISO 11140-4
BD8948X1 – Steam Sterilisers operating at 3.5 minutes at 134°C and 4 minutes at 132°C, Purple to Green, ISO 11140-5
KBD8948 – Steam Sterilisers operating at 3.5 minutes at 134°C and 4 minutes at 132°C, Purple to Green, Kit
KBD8948X1 – Steam Sterilisers operating at 3.5 minutes at 134°C and 4 minutes at 132°C, Purple to Green, Kit
Process Challenge Devices (PCD) Helix Type and Specific Indicators (Type 2)
- Terragene Helix Process Challenge Devices are designed to evaluate the safe release of the steriliser load, especially for hollow instruments.
- Terragene Specific Indicators offer a range of Type 2 indicators for Steam, Ethylene Oxide (Eto / EO), Formaldehyde (LTSF) and Hydrogen Peroxide (H₂O₂)
- Terragene Helix PD provides a Bowie & Dick simulation test to monitor the sterilisers performance, empty.
Metal Capsule PCD for Steam
CDPCD2X025/M, 0.25 m Long
CDPCD2X050/M, 0.5 m Long
CDPCD2X075/M, 0.75 m Long
CDPCD2X10/M, 1 m Long
CDPCD2X15/M, 1.5 m Long
CDPCD2X30/M, 3 m Long
CDPCD2X45/M, 4.5 m Long
Plastic Capsule PCD for Steam, Ethylene Oxide, Formaldehyde, Hydrogen Peroxide
CDPCD2X025/P, 0.25 m Long
CDPCD2X050/P, 0.5 m Long
CDPCD2X075/P, 0.75 m Long
CDPCD2X10/P, 1 m Long
CDPCD2X15/P, 1.5 m Long
CDPCD2X30/P, 3 m Long
CDPCD2X45/P, 4.5 m Long
Indicators for Helix System
PCD-A-3.5Y, Steam, 3.5 minutes at 134°C, Black to Yellow
PCD-A-5.3Y, Steam, 5.3 minutes at 132°C or 15 minutes at 121°C, Black to Yellow
PCD-A-7.0Y, Steam, 7 minutes at 132°C or 20 minutes at 121°C, Black to Yellow
PCD-A-9.0Y, Steam, 9 minutes at 134°C, Black to Yellow
PCD-A-18.0Y, Steam, 18 minutes at 134°C, Black to Yellow
PCD-A-E1, Ethylene Oxide, Sky Blue to Green
PCD-A-F1, Formaldehyde, Bordeaux/Red to Green
PCD-A-P1, Hydrogen Peroxide, Purple to Green
PCD-A-3.5BD, Bowie & Dick Simulation Test, Steam, 3.5 minutes at 134°C, Blue to Black
Chemdye Type 4 Chemical Indicators
- Terragene Chemdye Type 4 internal control strip indicators are designed to rapidly show if critical parameters of the sterilisation process have been reached, ensuring appropriate penetration of the sterilising agent inside the package.
- Terragene Chemdye chemical indicators offer a distinct colour change when exposed, to ensure the stated values (SVs) of the critical process variables.
Chemical Indicator Strips (Type 4)
CD16, Ethylene Oxide (EtO / EO), 600 mg/l EO, RH 60%, 30°C for 30 minutes or 600 mg/l EO, RH 60%, 54°C for 20 minutes, Purple to Brown, Double Strips
CD20, Multi-variable, Steam, 121°C for 15 minutes or 134°C for 3.5 minutes, Purple to Green
CD22, Steam, 121°C for 10 minutes or 134°C for 2 minutes, Blue to Black
CD202, Multi-variable, Steam, 121°C for 15 minutes or 134°C for 3.5 minutes, Blue to Black, Double Strips
CD29, Multi-variable, Steam, 121°C for 15 minutes or 134°C for 3.5 minutes, Yellow to Dark Brown/Black, Double Strips
CD29-AD, Multi-variable, Steam, 121°C for 15 minutes or 134°C for 3.5 minutes, Yellow to Dark Brown/Black, Self Adhesive Double Strips
CD30, Multi-variable, Dry Heat, 160°C for 40 minutes or 180°C for 20 minutes, Dark Blue to Brown
CD32, Dry Heat, 160°C for 40 minutes, Dark Blue to Brown
CD40, Hydrogen Peroxide (H₂O₂), 6 minutes for 50°C, 2,3 mg/l H₂O₂, Purple to Green
CD42, Hydrogen Peroxide (H₂O₂), 6 minutes for 50°C, 2,3 mg/l H₂O₂, Red to Yellow
CD50, Multi-variable, Formaldehyde (LTSF), 30 minutes for 60°C, 1 mol/l FORM, Bordeaux/Red to Green
Chemical Tubes (Type 4)
CD210, Multi-variable Glass Ampoule, Steam Sterilisation of Fluids, 121°C for 15 minutes or at 126°C for 10 minutes, Black Spot, Red to Green
CD220, Multi-variable Glass Ampoule, Steam Sterilisation of Fluids, 134°C for 3 to 3.5 minutes, Yellow Spot, Red to Green
CD250, Multi-variable Glass Ampoule, Dry Heat, 160°C for 120 minutes, 170°C for 60 minutes or 18°C for 35 minutes, White Spot, Red to Green
Moving Front Chemical Integrators / Indicators (Type 5)
- Terragene Integron moving front integrators were developed for monitoring steam sterilisation processes between 118°C and 13°C, by monitoring all critical parameters of steam sterilisation (temperature, time, steam quality).
- Chemical pellets melt and migrates as a dark bar along the paper wick, through a zone marked as ACCEPT or REJECT, thus indicating whether sterilisation conditions were met or not.
Unique Point Chemical Integrator (Type 5)
- Terragene Integron Unique Point Integrators were developed for verification of Steam sterilisation cycles between 121°C and 135°C.
- Terragene Integron Unique Point Integrators ensure an adequate control of the effectiveness of sterilisation processes (temperature, time, steam quality).
EO Two Level Integrator (Type 5)
- Terragene Two Level Integrator were developed to control Ethylene Oxide sterilisation process.
- The two level indicator was designed for: Level 1, is the exposure level which indicates exposure to Ethylene Oxide and Level 2 is the integration level, consisting of a purple/brown ink dot that turns to green as it integrates all the critical parameters of sterilisation process (time, temperature, humidity and Ethylene Oxide concentration).
- The Terragene EO Two Level Integrator mimics the death curve of a theoretical Bacillus atrophaeus spore population.
| Product Code | Product Description | Pack Size | Quote |
|---|---|---|---|
| Product Code | Product Description | Pack Size | Quote |
|---|---|---|---|
| Product Code | Product Description | Pack Size | Quote |
|---|---|---|---|
| Product Code | Product Description | Pack Size | Quote |
|---|---|---|---|
| Product Code | Product Description | Pack Size | Quote |
|---|---|---|---|
| Product Code | Product Description | Pack Size | Quote |
|---|---|---|---|
| Product Code | Product Description | Pack Size | Quote |
|---|---|---|---|
| Product Code | Product Description | Pack Size | Quote |
|---|---|---|---|
Applications
- Life Science
- Laboratory Infection Control
- CSD
- Healthcare Facilities
- Dental
Relevant Product
Downloads
To access a copy of the eBook or product brochure, please complete and submit a copy of the Downloads form below.